Product Application
Contact Us
Telephone:+86-311-83933866
E-mail:jl.dong@mtmems.com
Address:No.1, Meitai Road, Luquan District, Shijiazhuang City
Pressure-temperature composite sensor
Product Features
● Short temperature response time
● Low cost
● High overload
● High reliability
● Leadless chip
● Customization supported
Contact Us
Product Classification:
Performance metrics
Test conditions (unless otherwise specified): room temperature, 5 ± 0.25 V.
| Indicator Name | Unit | Parameter |
| Measurement range | MPa | 0 ~ 1, 0 ~ 3.5 |
| Type of stress | / | Absolute pressure |
| Overload pressure | / | 3 times |
| Overall accuracy | %.Vcc | ±1.5 (-40℃ ~ 135℃) |
| Operating temperature | Celsius | -40~135 |
| Storage temperature | Celsius | -40~150 |
| Supply voltage | VDC | 5 ± 0.25 |
| Overvoltage | VDC | 20 |
| Load resistance | kΩ | ≥10 |
| Signal output | VDC | 0.5~4.5 |
| Operating current | mA | ≤10 |
| Response time | Ms. | ≤10 |
| NTC temperature measurement range | Celsius | -40~150℃ |
| Resistance value at 25℃ | kΩ | 10 ± 1% |
| B25/100 value | B25/100 | 4005 ± 1% |
| Install the thread | / | M12×1.25 (customizable) |
| Electrical connector | / | TE 1-967640-1/UScar 120-2-004-1-202 |
Application fields

● Heat pump air conditioning systems, etc.
Main dimensions and interface definitions

| Output interface wiring definition | ||
| Connector Definition | Symbol definition | Symbol Legend |
| 1 | GND | Power ground |
| 2 | NTC | Temperature output |
| 3 | Vout | Pressure output |
| 4 | VCC | Power supply |
Key words:
Online consultation
If you have any questions about our products and services, please contact us!
recommend products