Pressure-temperature composite sensor
+
  • Pressure-temperature composite sensor

Pressure-temperature composite sensor

Product Features ● Short temperature response time ● Low cost ● High overload ● High reliability ● Leadless chip ● Customization supported



Performance metrics

Test conditions (unless otherwise specified): room temperature, 5 ± 0.25 V.

Indicator Name Unit Parameter
Measurement range MPa 0 ~ 1, 0 ~ 3.5
Type of stress / Absolute pressure
Overload pressure / 3 times
Overall accuracy %.Vcc ±1.5 (-40℃ ~ 135℃)
Operating temperature Celsius -40~135
Storage temperature Celsius -40~150
Supply voltage VDC 5 ± 0.25
Overvoltage VDC 20
Load resistance ≥10
Signal output VDC 0.5~4.5
Operating current mA ≤10
Response time Ms. ≤10
NTC temperature measurement range Celsius -40~150℃
Resistance value at 25℃ 10 ± 1%
B25/100 value B25/100 4005 ± 1%
Install the thread / M12×1.25 (customizable)
Electrical connector / TE 1-967640-1/UScar 120-2-004-1-202

Application fields

● Heat pump air conditioning systems, etc.

Main dimensions and interface definitions

Output interface wiring definition
Connector Definition Symbol definition Symbol Legend
1 GND Power ground
2 NTC Temperature output
3 Vout Pressure output
4 VCC Power supply