Door pressure sensor
+
  • Door pressure sensor

Door pressure sensor

Product Features ● The measurement range for ambient pressure can reach 140 kPa. ●SO8 standard package ● PSI5 V1.3 and 2.1 compatible communication interface ●OTP programming allows selection of the on-chip low-pass filter type (FIR and IIR). ● Can output three types of signals: ambient pressure, relative differential pressure, and temperature.



Performance metrics

Test conditions: Room temperature (25℃ ± 2℃)

Performance parameters Unit MSP475
Maximum range of environmental stress kPa 50~140
Environmental stress output LSB 0~4818
Environmental pressure accuracy kPa ±3
Maximum range of relative pressure variation -150 to 1000
Relative Change Pressure Sensitivity LSB/‰ 0.5/2
Relative change pressure sensitivity accuracy % ±6
Relative change pressure zero bias LSB ±0.5
Temperature range K -40~150
Temperature sensitivity LSB/K 1
Temperature output accuracy K ±10
Operating voltage V 4.5–11
Operating temperature Celsius -40~125
Storage temperature Celsius -55~135
Pressure-resistant overload kPa 600
Impact-resistant g ±2000
Output format - PSI5
Encapsulation - SO8

Application areas

● Used in airbag collision systems

Outline dimensions and pin definitions

Pin number Definition Instructions
1 GND Earth
2 VSSI ASIC land
3 VDDI Internal power supply
4 GND Earth
5 GND Earth
6 Idata PSI5 interface
7 VDD Power supply
8 GND Earth

Key words:

Online consultation

If you have any questions about our products and services, please contact us!